QTY. 1. VG ELEMENTAL / THERMO-SCIENTIFIC PLASMA QU...
QTY. 1. VG ELEMENTAL / THERMO-SCIENTIFIC PLASMA QUAD 3 ICP/MS (INDUCTI...
Call for pricing: 409-942-4224
QTY. 1. VG ELEMENTAL / THERMO-SCIENTIFIC PLASMA QUAD 3 ICP/MS (INDUCTIVITY COUPLED PLASMA / MASS SPECTROMETER) SLOT+MO-PQ3-145. INCLUDES NESLAB CFT-75 REFRIGERATED RECIRCULATOR, MODEL: CFT-75, RMT STRT PUMP PD-2 200-230V, 60HZ, 1PH. INCLUDES.1. EDWARDS ACTIVE GAUGE, AIM-S-NW25,PART NO.:D14641000,SERIAL NO.:027472743 (NOTE ON GAUGE ANALYZER PLASMA WILL NOT STABILIZE..) .1. BOC EDWARDS ACTIVE GAUGE, AIM-S-NW25,PART NO.:D14641000,SERIAL NO.:056193758, (NOTE ON GAUGE ANALYZER PRESSURE WILL NOT STABILIZE.) .1. EDWARDS ACTIVE GAUGE, AIM-S-NW25,PART NO.:D14641000,SERIAL NO.:027312091 .1.EDWARDS ACTIVE GAUGE,AIM-S-NW25,PART NO.-D14641000,SERIAL NO.-006527606,(NOTE ON GAUGE PRESSURE WILL NOT STABILIZE.) .1.EDWARDS ACTIVE GUAGE,AIM-S-NW25,PART NO.-D14641000,SERIAL NO.-027559052,(NOTE ON GAUGE PRESSURE WILL NOT STABILIZE. ) .MISC. GLASSWARE. 1. THERMO ELECTRON CORP.,FI450-05,SERIAL NO.-3201192,ICP-MS TORCH 1.5MM INJECTION. 2.PRECISION GLASS BLOWING 450-05 ICP-MS TORCH,1.5MM,SERIAL NO.-3201192.1. VG ELEMENTAL 1999 ICP-MS SEMINAR SERIES USERS MANUAL..1. VG ELEMENTAL PLASMA QUAD USERS MANUAL.1. VG ELEMENTAL PLASMA QUAD 3 USERS MANUAL.1. VG ELEMENTAL PLASMA LAB USER GUIDE.1. VG ELEMENTAL PLASMA QUAD SUPPLIERS MANUAL.3. VG ELEMENTAL PLASMA QUAD 3 ICP-MS OPERATOR TRAINING .1. VG ELEMENTAL PART W/MANIFOLD.This instrument was introduced in 1996. The primary improvements were that the STE instrument electronics controller of the PQ2 was replaced by commercially available programmable logic controller components. A fully automated torch alignment platform in the X, Y, and Z directions was used and an insert able torch screen could be fitted for use in cool plasma experiments. The vacuum system was all Edward's turbo molecular and rotary pumps and the lens stack was modified for improved sensitivity and background. The quadrupole and quadrupole electronics were redesigned for improved stability and ion transmission, and a dual-mode electron multiplier system in which analog and pulse counting is conducted simultaneously, became available. The physical size of the instrument was reduced to the size of a large table and the noise level reduced dramatically. Instrument sensitivity for a standard PQ3 using standard pneumatic nebulization was in the range of 30-60 mcps/ppm. Using the optional S-option pumping mode, sensitivity could be increased to 150 to 300 mcps/ppm depending on the element. Instrument background was 10 cps at 220 amu.